Requirements for functional doors at a glance
Doors are designated as functional doors when, unlike standard interior doors (which connect two rooms), they have to meet more stringent requirements.
These higher requirements include, amongst others:
- fire protection
- smoke protection
- sound insulation
- Radiation protection
- Burglary resistance
- Accessibility
- Climate stability
- Bullet resistance
- Suitability for damp rooms
- Suitability for wet rooms
- Mechanical stress
- Doors in escape routes
- Automation
- Access control
- Burglar-resistant
- Vandal-proof
- Suicide prevention
So check ..... what is installed!
The requirements placed on doors and building components are generally verified through controls, some of which are highly complex.
Building regulations also impose requirements on doors according to the regulations. This is particularly the case when it comes to fire protection or sound insulation. Legislators and accident insurance providers also impose high standards on doors in connection with escape route safety.
Depending on the area of application, however, radiation protection (e.g. in X-ray rooms), burglary and bullet resistance, or accessibility also play a significant role. In specific buildings, doors must be equipped with burglary and escape resistance, vandalism protection and/or suicide prevention features.
In buildings with high footfall or high general wear and tear, doors are often subjected to particular mechanical loads.
For other building components such as windows and exterior doors, the special functions generally involve fire and smoke protection, as well as burglary resistance or sound insulation. In rare cases, bullet resistance is also required.
TPO produces and supplies the right windows and doors for almost every range of applications.
Escape route doors
Evacuating safely – the top priority in the event of danger
If people need to evacuate buildings, it must be ensured that everyone can reach the open air or safe areas via appropriate exits.
As ‘normal’ entrances and exits are usually not designed to cope with the expected crowds in the event of danger, escape routes are planned that include doors along their path.
The maximum length of an escape route to the exit or safe area is fixed and must generally not exceed 35 metres (shorter distances are possible).
Doors in escape routes must open ‘easily and to their full width’ in the direction of escape (both interior doors and exterior doors). It is important that the widths of escape routes are fixed according to the risk assessment and adhered to. Advice on the clear passage width of doors in escape routes can be found here.
A distinction is made between emergency exit doors and panic doors in escape routes.
Get out safely - with and without panic
Emergency exit doors are used when there are people in the building who are familiar with the local conditions (offices, business premises, nurseries, etc.). These doors are operated using standard door handles. As a rule, fittings/locks in accordance with DIN EN 179 are used.
Panic doors are used when people in the building are unfamiliar with the situation or panic is to be expected. This is usually the case in public buildings, a cinema, a place of assembly, etc. Panic doors have push bars that open the doors as soon as pressure is exerted against these bars. As a rule, fittings/locks in accordance with DIN EN 1125 are used.
In connection with escape route doors, there are often additional requirements for securing the doors or monitoring these components.